RWC Ke/Kh
WATER COOLED CHILLERS WATER CONDENSED FOR INDOOR INSTALLATION EQUIPPED WITH BRUSHLESS OIL-FREE TURBOCOR COMPRESSORS
Cooling capacity from 210 kW to 1800 kW
The monoblock water-cooled chillers of RWC series are suitable for external installation and are particularly indicated for liquid cooling in air conditioning and industrial process plants, where high efficiency with partial loads, quietness and long lifetime must be granted.
Units are equipped with magnetic levitation centrifugal compressors and flooded shell and tube evaporator. The magnetic levitation technology means that there is no mechanical friction in the compressor, allowing oil-free refrigeration circuits.
All the units are totally factory assembled and tested following specific quality procedures. They are also totally hydraulically and electrically connected so, once on site, they can be quickly installed. Before final test, cooling circuits are pressure tightness tested and charged with the refrigerant. Therefore, once on site, the units must only be positioned and hydraulically and electrically connected.
Emicon
Emicon
RWH VS Ke/Kh
WATER COOLED CHILLERS WATER CONDENSED FOR INDOOR INSTALLATION EQUIPPED WITH SCREW COMPRESSORS FULL INVERTER AND SHELL AND TUBE EXCHANGER
Cooling capacity from 269 kW to 2020 kW
The modular water cooled chillers of RWH VS KE series are suitable for external installations and are particularly indicated to cool fluid solutions for industrial applications or air conditioning systems of commercial sector, where it is necessary to grant a very low environmental impact, class A efficiency and the compliance with the seasonal efficiency requirements specified on the EU Regulation 2016/2281.
The units of this series are equipped with two semi-hermetic screw compressors; each one provided with constant control of the cooling capacity through dedicated external inverter, each compressor operates on a single independent circuit thus ensuring the highest reliability.
All the units are totally factory assembled and tested, following specific quality procedures. Besides, they are hydraulic, cooling and electrical connected allowing a quick installation once on site. Before the test, the cooling circuits of each unit are subjected to a pressure test and then charged with refrigerant and non-freezing oil. Therefore, once on site, the units must only be positioned and electrically and hydraulically connected.
Emicon
Emicon
RWE N Kc/Kr
WATER COOLED CHILLERS WATER CONDENSED FOR INDOOR INSTALLATION EQUIPPED WITH SCROLL COMPRESSORS
Cooling capacity from 54 kW to 476 kW
The water cooled chillers of RWE N series are designed for indoor installation and are particularly suitable for small and medium sized air conditioning systems with different applications like multiple dwellings and commercial application, whereas a water ring for heat dissipation is available. They are all available with 1 or 2 cooling circuits.
The units have been designed to be extremely compact, with anyway an easy access for both ordinary and extraordinary maintenance. Thanks to their compact dimensions (for the whole range, the width is 750mm) and to the several available options, these units are particularly easy to install also in small spaces, with no building works.
They are completely factory assembled and tested and supplied with refrigerant and non-freezing oil charge. Therefore, once on site, the units only need to be positioned and electrically and hydraulically connected.
Emicon
Emicon
RAS Kp
OUTDOOR MONOBLOCK AIR COOLED CHILLERS EQUIPPED WITH SEMIHERMETIC RECIPROCATED COMPRESSORS AND AXIAL FANS
Cooling capacity from 20 kW to 420 Kw
The packaged air cooled chillers are suitable for outdoor installation. The refrigerant used is Propane. Depending on the capacity required the units are available with 1 or 2 independents cooling circuits equipped with 1 or 2 compressors for each circuit.
Thanks to the many available options, these chillers are particularly versatile and are easily adaptable to the different types of plants, where production of chilled water is required.
Emicon
Emicon
RAH VS F Ke/Kh
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING EQUIPPED WITH SCREW INVERTER COMPRESSORS AND AXIAL FANS
Cooling capacity from 308 kW to 1837 Kw
Packaged air cooled chillers of RAH VS F eries with integrated free cooling section are suitable for outdoor installation and can be used to cool glycol fluid solutions for air conditioning or in industrial applications.
Semi-hermetic screw inverter technology allows to reach great efficiency improvements at part load, if compared to the other traditional systems for cooling capacity control.
The integrated free cooling section allows to partially or totally recover cooling capacity from external air without big consumption of energy. Units are equipped with an additional coil crossed by the liquid to be chilled and invested by the complete air flow generated by the condenser fans.
The combination of high efficiency finned exchangers with the thermophysical purity of refrigerant used, almost glide-free during the changes of state, allows having nominal EER near 3 with ESEER above 5 in mechanical operation.
These units have been designed considering limited space requirements and keeping, at the same time, high cooling performances. Such result has been attained with high-quality and up-to-date components.
All units are completely assembled and tested in the factory with specific quality procedures and are already equipped with all necessary hydraulic, refrigerant and electrical connections for a quick installation on site.
Before factory testing, cooling circuits are tested under pressure and then supplied with refrigerant and a non-freezing oil charge.
Emicon
Emicon
RAH F Ke/Kh
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING EQUIPPED WITH SCREW COMPRESSORS AND AXIAL FANS
Cooling capacity from 338 kW to 1586 kW
Packaged air cooled chillers of RAH F series with integrated free cooling section are suitable for outdoor installation and can be used to cool glycol fluid solutions for air conditioning or in industrial applications.
Semi-hermetic screw technology allows to reach great efficiency improvements at part load, if compared to the other traditional systems for cooling capacity control.
The integrated free cooling section allows to partially or totally recover cooling capacity from external air without big consumption of energy. Units are equipped with an additional coil crossed by the liquid to be chilled and invested by the complete air flow generated by the condenser fans.
The combination of high efficiency finned exchangers with the thermophysical purity of refrigerant used, almost glide-free during the changes of state, allows having nominal EER near 3 with ESEER above 4, 5 in mechanical operation. EER can exceed 25 in free-cooling mode.
These units have been designed considering limited space requirements and keeping, at the same time, high cooling performances. Such result has been attained with high-quality and up-to-date components. All units are completely assembled and tested in the factory with specific quality procedures and are already equipped with all necessary hydraulic, refrigerant and electrical connections for a quick installation on site.
Before factory testing, cooling circuits are tested under pressure and then supplied with refrigerant and a non-freezing oil charge.
Emicon
Emicon
RAE F Kc/Kr
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING, EQUIPPED WITH SCROLL COMPRESSORS AND AXIAL FANS
Cooling capacity from 91 kW to 853 kW
Packaged air cooled chillers of RAE F series with integrated free cooling section are suitable for outdoor installation and can be used to cool glycol fluid solutions for air conditioning or in industrial applications.
Multiscroll technology allows to reach great efficiency improvements at part load, if compared to the other traditional systems for cooling capacity control.
The integrated free cooling section allows to partially or totally recover cooling capacity from external air without big consumption of energy. Units are equipped with an additional coil crossed by the liquid to be chilled and invested by the complete air flow generated by the condenser fans. These units have been designed considering limited space requirements and keeping, at the same time, high cooling performances. Such result has been attained with high-quality and up-to-date components.
All units are completely assembled and tested in the factory with specific quality procedures and are already equipped with all necessary hydraulic, refrigerant and electrical connections for a quick installation on site. Before factory testing, cooling circuits are tested under pressure and then supplied with refrigerant and a non-freezing oil charge.
Emicon
Emicon
RAC MC HE Ke/Kh
HIGH EFFICIENCY AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION EQUIPPED WITH BRUSHLESS OIL-FREE TURBOCOR COMPRESSORS, AXIAL FANS AND MICROCHANNEL CONDENSING COILS
Cooling capacity from 443 kW to 1396 Kw
The monoblock air-cooled chillers of RAC MC series are suitable for external installation and are particularly indicated for liquid cooling in air conditioning and industrial process plants, where high efficiency with partial loads, quietness and long lifetime must be granted.
The extreme compactness of both compressor and condensing section has allowed to produce chillers with a compact design and resulting reduced weight if compared to traditional chillers with same cooling capacity. This aspect connected to the lack of lubricating oil in the cooling circuit, allows to significantly reduce the maintenance costs and to make the most of the heat exchangers in their global thermal exchange surface.
All the units are totally factory assembled and tested following specific quality procedures. They are also totally hydraulically and electrically connected so, once on site, they can be quickly installed. Before final test, cooling circuits are pressure tightness tested and charged with the refrigerant. Therefore, once on site, the units must only be positioned and hydraulically and electrically connected.
Emicon
Emicon
RAH MC VS Ka/Kh/Ke
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION EQUIPPED WITH INVERTER SCREW COMPRESSORS, AXIAL FANS AND MICROCHANNEL CONDENSING COILS
Cooling capacity from 306 kW to 1555 Kw
The air-cooled chillers of this serie are suitable for outdoor installation and are particularly suitable for cooling liquid solutions, used for industrial applications or air conditioning systems, in which it is necessary to ensure excellent performance and low environmental impact.
The machines are designed as outdoor units in compliance with European standards EN378 and its updates and are able to meet the seasonal efficiency requirements established by Regulation (EU) 2016/2281-LOT21.
The units of this series are equipped with two screw compressors, each with a continuous control of the cooling capacity, realized thanks to an in-built inverter. Each compressor operates on a single totally independent circuit, thus ensuring the maximum reliability.
All the units are totally factory assembled and tested, following specific quality procedures. Besides, they are totally hydraulic, cooling and electrical connected, permitting a quick installation once on site. Before the test, the cooling circuits of each unit are subject to a pressure tightness test and then charged with Refrigerant and non-freezing oil. Therefore, once on site, the units must be only positioned and electrically and hydraulically connected.
The reduction of the sound level in the silenced version is reached thanks to refrigerant/air exchangers with wider surfaces and a compressor cabinet insulated with higher thickness soundproof material.
Emicon
Emicon
RAE N MC Kc/Kr
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION EQUIPPED WITH SCROLL COMPRESSORS, AXIAL FANS AND MICROCHANNEL CONDENSING COILS
Cooling capacity from 78 kW to 636 Kw
Packaged air cooled chillers of RAE N MC series are suitable for outdoor installation and can be used to cool pure fluid solutions for air conditioning or in industrial applications.
Multiscroll technology allows to reach great efficiency improvements at part load, if compared to the other traditional systems for cooling capacity control.
All the units are totally factory assembled and tested, following specific quality procedures. Besides they are totally hydraulic, cooling and electrical connected permitting a quick installation once on site. Before the test the cooling circuits of each unit are subjected to a pressure test and then charged with Refrigerant R410A or R454B and non-freezing oil. So, once on site, the units must be only positioned and electrically and hydraulically connected.
Reduced sound level in versions S is realised by using condensers with larger surface areas as well as soundproofed compressor cabinets.
Emicon
Emicon
RAE N S Kc/Kr
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION EQUIPPED WITH SCROLL COMPRESSORS AND AXIAL FANS
Cooling capacity from 143 kW to 640 kW
Packaged air cooled chillers of RAE N S series are suitable for outdoor installation and can be used to cool pure fluid solutions for air conditioning or in industrial applications.
Multiscroll technology allows to reach great efficiency improvements at part load, if compared to the other traditional systems for cooling capacity control.
The coupling of high-efficiency finned exchangers and the thermo physical purity of R410A or R454B refrigerant, particularly glide-free at state exchanges, allows this range to attain EER nominal values close to 3.
These units have been designed considering limited space requirements and keeping, at the same time, high cooling performances. Such result has been attained with high-quality and up-to-date components.
All units are completely assembled and tested in the factory with specific quality procedures and are already equipped with all necessary hydraulic, refrigerant and electrical connections for a quick installation on site.
Before factory testing, cooling circuits are tested under pressure and then supplied with refrigerant and a non-freezing oil charge.
Emicon
Emicon
RAE N HE Kc
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION EQUIPPED WITH SCROLL COMPRESSORS AND AXIAL FANS
Cooling capacity from 18 kW to 195 Kw
Packaged air cooled chillers of RAE N series are suitable for outdoor installation and can be used to cool pure fluid solutions for air conditioning or in industrial applications.
All the units are totally factory assembled and tested, following specific quality procedures. Besides they are totally hydraulic, cooling and electrical connected permitting a quick installation once on site. Before the test the cooling circuits of each unit are subjected to a pressure test and then charged with Refrigerant and non-freezing oil. So, once on site, the units must be only positioned and electrically and hydraulically connected.
For versions S, the reduction of the sound level is achieved thanks to an increase of the condensing surfaces, to the fan speed reduction and to the soundproofed compressor cabinet.